Product Introduction
Satellite IR imaging spectrograph is composed of middle- and LWIR imaging thermal imaging smodule and multi-spectrum IR optical system, covering spectral imaging thermal imaging module, MWIR cooled detector, LWIR cooled detector, imaging measurement circuit, driver control circuit, filtering module and anti-irradiation structure. The spectral response ranges are 3.7μm~4.8μm and 7.7μm~9.5μm. multi-spectrum imaging can be realized by a dual-band IR optical lens introducing the narrow band filter of the optical system.
The product adopts non-uniformity correction, blind pixel compensation, image filtering, image intensification, linear stretching, automatic dimming and other intelligent image processing algorithms, to ensure good image quality and characteristic measurement. Characterized by high sensitivity, easy integration, multiple interfaces, high reliability and strong expandability among others, the imager can work around the clock.
Product Features
· Dual-band imaging alternating output and single-band imaging output functions;
· Fixed channel measurement and multi-channel measurement imaging functions;
· Temperature focus compensation and autofocus functions;
· High stability ≤±0.1%, repeatability ≤±0.5%, linearity ≤1%;
· Four-way stepper motor control and more-than-10-way temperature measurement functions;
· External synchronization and analog telemetry functions;
· Anti single event upsets, single event locking and other space irradiation functions;
· Long-term working ability in vacuum environment.
Technical Indicators
Satellite IR imaging spectrograph | ||||
MWIR Cooled spectrograph | Number of pixels | 320×256 | ||
pixel size | 30μmx30μm | |||
Spectral range | 3.7μm~4.8μm | |||
Non-conformity | 0.5% (Exposure time3ms@25℃) | |||
NETD | 12mK | |||
LWIR Cooled spectrograph | Number of pixels | 320×256 | ||
Pixel size | 30μmx30μm | |||
Spectral range | 7.7μm~9.5μm | |||
Non-conformity | 0.5% (Exposure time 400μs@25℃) | |||
NETD | 18mK | |||
Rotating filter wheel | Operating mode | Positioning mode, polling mode | ||
Filter piece holes | MW, LWIR each with 6 holes | |||
Positioning error | 1.8° | |||
Speed error | 1% | |||
Other parameters | Frame rate | 40Hz/20Hz/10Hz/5Hz/2.5Hz | ||
Calibration coefficients stored | each 12 groups | |||
Stability | ≤±0.1% | |||
Repeatability | ≤±0.5% | |||
Linearity | ≤1% | |||
Electrical interfaces | Video output | CameraLink | ||
Communication interface | CAN2.0 | |||
External sync | RS422 | |||
telemetering interface | Telemetering analog | |||
Environmental adaptation | Thermal shock | Test temperature: -45℃~+70℃, number of cycles: 10 | ||
Thermal circulation | Test temperature: -35℃~+60℃, number of cycles: 20 | |||
Thermal vacuum | Test temperature: -35℃~+60℃ |